AMB ON Plus 6 kVA, 10 kVA UPS Series G2

Download flyer

Features

  • High Reliability
  • Full-Digital Control Technology
  • Strong Application Adaptability
  • Environmentally green and safe
  • Comprehensive Alarm Protection
  • Outstanding Energy Efficiency
  • Green Power Bidirectional Protection
  • Intelligent and User Friendly

SPECIFICATION

MODEL AMB-ON-Plus-6K(L) AMB-ON-Plus-10K(L)
Phase 1 phase in / 1 phase out 1 phase in / 1 phase out
Capacity 6000 VA / 6000 W 10000 VA / 10000 W
INPUT
Nominal Voltage 208/220/230/240 VAC 208/220/230/240 VAC
Voltage Range 110~300VAC ±3% @ 60% load;

176~300VAC ±3% @ 100% load

110~300VAC ±3% @ 60% load;

176~300VAC ±3% @ 100% load

Frequency Range 46~54 Hz or 56~64 Hz; 40~70 Hz (generator mode) 46~54 Hz or 56~64 Hz; 40~70 Hz (generator mode)
Power Factor ≧ 0.99 @ full load ≧ 0.99 @ full load
THDi < 4% @ 100% R load < 4% @ 100% R load
OUTPUT
Output Voltage 208*/220/230/240 VAC 208*/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1% ± 1%
Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.) 3:1 (max.)
Harmonic Distortion ≦ 1% THD (Linear Load); ≦ 4% THD (Non-linear Load) ≦ 1% THD (Linear Load); ≦ 4% THD (Non-linear Load)
Transfer Time – AC Mode to Batt. Mode Zero Zero
Transfer Time – Inverter to Bypass Zero Zero
Waveform (Batt. Mode) Pure Sinewave Pure Sinewave
Overload – AC Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1 min, >150% immediate switch to bypass 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1 min, >150% immediate switch to bypass
Overload – Battery Mode 100%~110%: 3 min, 110%~130%: 30 s,

>130%: immediately

100%~110%: 3 min, 110%~130%: 30 s,

>130%: immediately

EFFICIENCY
AC Mode 95% 95%
Battery Mode 92% 92%
BATTERY – STANDARD MODEL
Battery Type 12 V / 7 Ah 12 V / 9 Ah
Numbers 16 20
Typical Recharge Time 7 hours recover to 90% capacity 9 hours recover to 90% capacity
Charging Current (max.) 1 A ± 10% (Default) 1 A ± 10% (Default)
Charging Voltage 218.4 VDC ± 1% 240 VDC ± 1%
BATTERY – LONG-RUN MODEL
Battery Type Sealed, lead-acid battery Sealed, lead-acid battery
Numbers 16-20** 16-20**
Charging Current (max.) 2A ± 10% (Default) 1/2/4/6/8A adjustable 2A ± 10% (Default) 1/2/4/6/8A adjustable
Charging Voltage (13.65VDC × battery number) ± 1% (13.65VDC × battery number) ± 1%
INDICATORS
LCD Display UPS status, load level, battery level, input/ output voltage, discharge timer, and fault conditions UPS status, load level, battery level, input/ output voltage, discharge timer, and fault conditions
PHYSICAL – STANDARD MODEL
Dimension, D x W x H (mm) 369 x 190 x 688 442 x 190 x 688
Net Weight (kg) 55 74
PHYSICAL – LONG-RUN MODEL
Dimension, D x W x H (mm) 369 x 190 x 318 369 x 190 x 318
Net Weight (kg) 14 15
ENVIRONMENT
Operating Humidity < 95% RH @ 0-40°C (Non-condensing) < 95% RH @ 0-40°C (Non-condensing)
Noise Level Less than 55dB @ 1 Meter Less than 58dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows® Family, Linux and MAC Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser Power management from SNMP manager and web browser

 

AMB-On-Plus-6K-RT(L)/AMB-ON-Plus-10K-RT(L)

MODEL AMB-On-Plus-6K-RT(L) AMB-ON-Plus-10K-RT(L)
Phase 1 phase in / 1 phase out 1 phase in / 1 phase out
Capacity 6000 VA / 6000 W 10000 VA / 10000 W
INPUT
Nominal Voltage 208/220/230/240 VAC 208/220/230/240 VAC
Voltage Range 110~300VAC ±3% @ 60% load;

176~300VAC ±3% @ 100% load

110~300VAC ±3% @ 60% load;

176~300VAC ±3% @ 100% load

Frequency Range 46~54 Hz or 56~64 Hz; 40~70 Hz (generator mode) 46~54 Hz or 56~64 Hz; 40~70 Hz (generator mode)
Power Factor ≧ 0.99 @ full load ≧ 0.99 @ full load
THDi < 4% @ 100% R load < 4% @ 100% R load
OUTPUT
Output Voltage 208*/220/230/240 VAC 208*/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ± 1% ± 1%
Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.) 3:1 (max.)
Harmonic Distortion ≦ 1% THD (Linear Load); ≦ 4% THD (Non-linear Load) ≦ 1% THD (Linear Load); ≦ 4% THD (Non-linear Load)
Transfer Time – AC Mode to Batt. Mode Zero Zero
Transfer Time – Inverter to Bypass Zero Zero
Waveform (Batt. Mode) Pure Sinewave Pure Sinewave
Overload – AC Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1 min, >150% immediate switch to bypass 100-110% for 60 min, 110-125% for 10 min, 125%~150% 1 min, >150% immediate switch to bypass
Overload – Battery Mode 100-110% for 3 min, 110-130% for 30 s,

>130% immediately

100-110% for 3 min, 110-130% for 30 s,

>130% immediately

EFFICIENCY
AC Mode 95% 95%
Battery Mode 92% 92%
BATTERY
Battery Type Lead acid battery Lead acid battery
Numbers 16-20** 16-20**
Charging Current 2A (Default), 1/2/4/6/8A adjustable 2A (Default), 1/2/4/6/8A adjustable
Charging Voltage (13.65VDC × battery number) ± 1% (13.65VDC × battery number) ± 1%
PHYSICAL
Dimension, D x W x H (mm) 509 x 438 x 88 (2U) 509 x 438 x 88 (2U)
Net Weight (kg) 11 12.1
ENVIRONMENT
Operating Humidity 20-95% RH @ 0-40°C (Non-condensing) 20-95% RH @ 0-40°C (Non-condensing)
Noise Level Less than 55dB @ 1 Meter Less than 58dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows® Family, Linux and MAC Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser Power management from SNMP manager and web browser

Reviews

There are no reviews yet.

Be the first to review “AMB ON Plus 6 kVA, 10 kVA UPS Series G2”

Your email address will not be published. Required fields are marked *