AMB INVS-ON Series

Download Flyer

Feature
  • Self-consumption and feed-in to the grid
  • Programmable supply priority for PV, Battery or Grid
  • User-adjustable battery charging current suits different types
    of batteries
  • Programmable multiple operations modes: Grid tie, Off grid,
    and grid-tie with backup
  • Built-in Timer for various mode of on/off operation
  • Multiple communication for USB, RS-232, Modbus and SNMP
  • Monitoring software for real time status display and control
  • Custom-made firmware by ODM contract
  • Parallel operation up to 6 units for 5KW / 10KW and 15KW
Category:

Application

INVS-ON is a flexible and intelligent hybrid inverter which utilizes solar power, AC utility, and battery power source to supply continuous power. It’s a simple and smart solar power storage system for home users to
either store energy into a battery for night-time usage or use for self-consumption first depending on demands. Priority for power source is programmable through smart software. During night time or power failure, it will automatically consume reserved power from the battery. In this way, it will reduce dependence on the utility.

Specification

Model INVS-ON 2kW INVS-ON Plus ll 3kW INVS-ON Plus 5kW INVS-ON 10kW      INVS-ON 15kW
PHASE                                                         1-phase in / 1-phase out              3-phase in / 3-phase out
MAXIMUM PV
INPUT POWER
2250 W 4500 W 10000 W 14850 W 22500 W
RATED OUTPUT POWER 2000 W 3000 W 5000 W 10000 W 15000 W
MAXIMUM
CHARGING POWER
1200 W 2880W 4800 W 9600 W 15000 W
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage
/ Maximum DC Voltage
300 VDC / 350 VDC 360 VDC / 500 VDC 720 VDC / 900 VDC 720 VDC /
900 VDC
720 VDC / 900 VDC
Start-up Voltage
/ Initial Feeding Voltage
80 VDC / 120 VDC 116 VDC / 150 VDC 225 VDC / 250 VDC 225 VDC /
250 VDC
320 VDC / 350 VDC
MPP Voltage Range 120 VDC ~ 320 VDC 250 VDC ~ 450 VDC 250 VDC ~ 850 VDC 350 VDC ~
850 VDC
350 VDC ~ 850 VDC
Number of MPP Trackers
/ Maximum Input Current
1 / 1 x 15 A 1 / 1 x 18 A 2 / 2 x 10 A 2 / 2 x 18.6A 2/A:37.65A;B:18.A
GRID OUTPUT (AC)
Nominal Output Voltage 101/110/120
/127 VAC
                          208/220/230/240 VAC        230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range 88 – 127 VAC*                                   184 – 265 VAC* 184 – 265VAC*
per phase
184 – 264.5VAC
per phase
Nominal Output Current 18 A 13 A 21 A 14.5A per phase 21.7A per phase
Power Factor                                                                                                                              > 0.99
EFFICIENCY
Maximum Conversion
Efficiency (DC/AC)
95% 96% 96% 96% 96%
European Efficiency@
Vnominal
94% 95% 95% 95% 95%
OFF-GRID OPERATION
AC INPUT
AC Start-up Voltage
/Auto Restart Voltage
60 – 70 VAC
/ 85 VAC
               120 – 140 VAC / 180 VAC 120 – 140 VAC per phase / 180 VAC per phase 121 – 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range 80 – 130 VAC                             170 – 280 VAC 170 – 290 VAC
per phase
170 – 280 VAC
per phase
Maximum AC Input Current                                             30 A                                                                                                  40 A
PV INPUT (DC)
Maximum DC Voltage 350 VDC 500 VDC 900 VDC 900 VDC 900 VDC
MPP Voltage Range 150 VDC ~ 320 VDC 250 VDC ~ 450 VDC 250 VDC ~ 850 VDC 350 VDC ~
850 VDC
350 VDC ~ 850 VDC
Number of MPP Trackers
/Maximum Input Current
1 / 1 x 15 A 1 / 1 x 18 A 2 / 2 x 10A 2 / 2 x 18.6A 2 /A: 37.65A;B:
18.6A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 101/110/120
/127 VAC
208/220/
230/240 VAC
202/208/220
/230/240 VAC
230 VAC (P-N)
/ 400 VAC (P-P)
230 VAC (P-N)
/ 400 VAC (P-P)
Output Waveform                                                                                                                                                   Pure Sinewave
Efficiency (DC to AC) 90% 93% 91% 91%
HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage
/ Maximum DC Voltage
300 VDC
/ 350 VDC
360 VDC / 500 VDC 720 VDC / 900 VDC 720 VDC /
900 VDC
720 VDC / 900 VDC
Start-up Voltage
/ Initial Feeding Voltage
80 VDC / 120 VDC 116 VDC / 150 VDC 225 VDC / 250 VDC 320 VDC /
350 VDC
320 VDC / 350 VDC
MPP Voltage Range 150 VDC ~
320 VDC
250 VDC ~ 450 VDC 250 VDC ~ 850 VDC 350 VDC ~
850 VDC
350 VDC ~ 850 VDC
Number of MPP Trackers
/ Maximum Input Current
1 / 1 x 15 A 1 / 1 x 18 A 2 / 2 x 10A 2 / 2 x 18.6A 2 / A: 37.65A;
B: 18.6A
GRID OUTPUT (AC)
Nominal Output Voltage 101/110/
120/127 VAC
208/220/
230/240 VAC
202/208/220
/230/240 VAC
230 VAC (P-N)
/ 400 VAC (P-P)
230 VAC (P-N)
/ 400 VAC (P-P)
Output Voltage Range 88-127 VAC*                                                  184 – 265 VAC* 184 – 265 VAC*
per phase
184 – 264.5
VAC per phase
Nominal Output Current 18 A 13 A 21 A 14.5 A
per phase
21.7A per phase
AC INPUT
AC Start-up Voltage
/ Auto Restart Voltage
60 – 70 VAC
/ 85 VAC
                 120 – 140 VAC / 180 VAC 120 – 140 VAC per phase / 180 VAC per phase 121 – 140 VAC per phase
/ 180 VAC per phase
Acceptable Input
Voltage Range
80 – 130 VAC                                               170 – 280 VAC 170 – 290
VAC per phase
170 – 280
VAC per phase
Maximum AC Input Current                                             30 A                                                          40 A 40 A
BATTERY MODE
OUTPUT (AC)
Nominal Output Voltage 101/110/
120/127 VAC
208/220/
230/240 VAC
202/208/220
/230/240 VAC
230 VAC (P-N)
/ 400 VAC (P-P)
230 VAC (P-N)
/ 400 VAC (P-P)
Efficiency (DC to AC) 90% 93% 91% 91%
BATTERY & CHARGER
Nominal DC Voltage                                                                                                                                                                   48 VDC
Maximum Charging Current Default 25A, 5A – 25A
(Adjustable)
Default 25 A, 5A – 60A
(Adjustable)
Default 60A, 5A – 100A
(Adjustable)
Default 60A, 10A – 200A
(Adjustable)
Default 60A, 5A – 300A
(Adjustable)
GENERAL
PHYSICAL
Dimension, D x W x H (mm)                               107 x 438 x 480 204.2 x 460 x 600 167.2 x 500 x 622 219 x 650 x 820
Net Weight (kgs) 15.5 15.5 29 40 62
INTERFACE
Communication Port                                    RS-232/USB                                 RS-232/USB RS-232, USB
and Dry contact
Intelligent Slot                                         Optional SNMP, Modbus and AS-400 cards available
ENVIRONMENT
Humidity                                                                                                        0 ~ 90% RH (Non-Condensing)
Operating Temperature  0 to 40°C                                                                         -10 to 55°C
Altitude                                                                                                             Max. 2000 m**

Reviews

There are no reviews yet.

Be the first to review “AMB INVS-ON Series”

Your email address will not be published. Required fields are marked *