Application
INVS-ON is a flexible and intelligent hybrid inverter which utilizes solar power, AC utility, and battery power source to supply continuous power. It’s a simple and smart solar power storage system for home users to
either store energy into a battery for night-time usage or use for self-consumption first depending on demands. Priority for power source is programmable through smart software. During night time or power failure, it will automatically consume reserved power from the battery. In this way, it will reduce dependence on the utility.
Specification
Model | INVS-ON 2kW | INVS-ON Plus ll 3kW | INVS-ON Plus 5kW | INVS-ON 10kW | INVS-ON 15kW |
PHASE | 1-phase in / 1-phase out | 3-phase in / 3-phase out | |||
MAXIMUM PV INPUT POWER |
2250 W | 4500 W | 10000 W | 14850 W | 22500 W |
RATED OUTPUT POWER | 2000 W | 3000 W | 5000 W | 10000 W | 15000 W |
MAXIMUM CHARGING POWER |
1200 W | 2880W | 4800 W | 9600 W | 15000 W |
GRID-TIE OPERATION | |||||
PV INPUT (DC) | |||||
Nominal DC Voltage / Maximum DC Voltage |
300 VDC / 350 VDC | 360 VDC / 500 VDC | 720 VDC / 900 VDC | 720 VDC / 900 VDC |
720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage |
80 VDC / 120 VDC | 116 VDC / 150 VDC | 225 VDC / 250 VDC | 225 VDC / 250 VDC |
320 VDC / 350 VDC |
MPP Voltage Range | 120 VDC ~ 320 VDC | 250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 350 VDC ~ 850 VDC |
350 VDC ~ 850 VDC |
Number of MPP Trackers / Maximum Input Current |
1 / 1 x 15 A | 1 / 1 x 18 A | 2 / 2 x 10 A | 2 / 2 x 18.6A | 2/A:37.65A;B:18.A |
GRID OUTPUT (AC) | |||||
Nominal Output Voltage | 101/110/120 /127 VAC |
208/220/230/240 VAC | 230 VAC (P-N) / 400 VAC (P-P) | ||
Output Voltage Range | 88 – 127 VAC* | 184 – 265 VAC* | 184 – 265VAC* per phase |
184 – 264.5VAC per phase |
|
Nominal Output Current | 18 A | 13 A | 21 A | 14.5A per phase | 21.7A per phase |
Power Factor | > 0.99 | ||||
EFFICIENCY | |||||
Maximum Conversion Efficiency (DC/AC) |
95% | 96% | 96% | 96% | 96% |
European Efficiency@ Vnominal |
94% | 95% | 95% | 95% | 95% |
OFF-GRID OPERATION | |||||
AC INPUT | |||||
AC Start-up Voltage /Auto Restart Voltage |
60 – 70 VAC / 85 VAC |
120 – 140 VAC / 180 VAC | 120 – 140 VAC per phase / 180 VAC per phase | 121 – 140 VAC per phase / 180 VAC per phase | |
Acceptable Input Voltage Range | 80 – 130 VAC | 170 – 280 VAC | 170 – 290 VAC per phase |
170 – 280 VAC per phase |
|
Maximum AC Input Current | 30 A | 40 A | |||
PV INPUT (DC) | |||||
Maximum DC Voltage | 350 VDC | 500 VDC | 900 VDC | 900 VDC | 900 VDC |
MPP Voltage Range | 150 VDC ~ 320 VDC | 250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 350 VDC ~ 850 VDC |
350 VDC ~ 850 VDC |
Number of MPP Trackers /Maximum Input Current |
1 / 1 x 15 A | 1 / 1 x 18 A | 2 / 2 x 10A | 2 / 2 x 18.6A | 2 /A: 37.65A;B: 18.6A |
BATTERY MODE OUTPUT (AC) | |||||
Nominal Output Voltage | 101/110/120 /127 VAC |
208/220/ 230/240 VAC |
202/208/220 /230/240 VAC |
230 VAC (P-N) / 400 VAC (P-P) |
230 VAC (P-N) / 400 VAC (P-P) |
Output Waveform | Pure Sinewave | ||||
Efficiency (DC to AC) | 90% | 93% | 91% | 91% | |
HYBRID OPERATION | |||||
PV INPUT (DC) | |||||
Nominal DC Voltage / Maximum DC Voltage |
300 VDC / 350 VDC |
360 VDC / 500 VDC | 720 VDC / 900 VDC | 720 VDC / 900 VDC |
720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage |
80 VDC / 120 VDC | 116 VDC / 150 VDC | 225 VDC / 250 VDC | 320 VDC / 350 VDC |
320 VDC / 350 VDC |
MPP Voltage Range | 150 VDC ~ 320 VDC |
250 VDC ~ 450 VDC | 250 VDC ~ 850 VDC | 350 VDC ~ 850 VDC |
350 VDC ~ 850 VDC |
Number of MPP Trackers / Maximum Input Current |
1 / 1 x 15 A | 1 / 1 x 18 A | 2 / 2 x 10A | 2 / 2 x 18.6A | 2 / A: 37.65A; B: 18.6A |
GRID OUTPUT (AC) | |||||
Nominal Output Voltage | 101/110/ 120/127 VAC |
208/220/ 230/240 VAC |
202/208/220 /230/240 VAC |
230 VAC (P-N) / 400 VAC (P-P) |
230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range | 88-127 VAC* | 184 – 265 VAC* | 184 – 265 VAC* per phase |
184 – 264.5 VAC per phase |
|
Nominal Output Current | 18 A | 13 A | 21 A | 14.5 A per phase |
21.7A per phase |
AC INPUT | |||||
AC Start-up Voltage / Auto Restart Voltage |
60 – 70 VAC / 85 VAC |
120 – 140 VAC / 180 VAC | 120 – 140 VAC per phase / 180 VAC per phase | 121 – 140 VAC per phase / 180 VAC per phase |
|
Acceptable Input Voltage Range |
80 – 130 VAC | 170 – 280 VAC | 170 – 290 VAC per phase |
170 – 280 VAC per phase |
|
Maximum AC Input Current | 30 A | 40 A | 40 A | ||
BATTERY MODE OUTPUT (AC) |
|||||
Nominal Output Voltage | 101/110/ 120/127 VAC |
208/220/ 230/240 VAC |
202/208/220 /230/240 VAC |
230 VAC (P-N) / 400 VAC (P-P) |
230 VAC (P-N) / 400 VAC (P-P) |
Efficiency (DC to AC) | 90% | 93% | 91% | 91% | |
BATTERY & CHARGER | |||||
Nominal DC Voltage | 48 VDC | ||||
Maximum Charging Current | Default 25A, 5A – 25A (Adjustable) |
Default 25 A, 5A – 60A (Adjustable) |
Default 60A, 5A – 100A (Adjustable) |
Default 60A, 10A – 200A (Adjustable) |
Default 60A, 5A – 300A (Adjustable) |
GENERAL | |||||
PHYSICAL | |||||
Dimension, D x W x H (mm) | 107 x 438 x 480 | 204.2 x 460 x 600 | 167.2 x 500 x 622 | 219 x 650 x 820 | |
Net Weight (kgs) | 15.5 | 15.5 | 29 | 40 | 62 |
INTERFACE | |||||
Communication Port | RS-232/USB | RS-232/USB | RS-232, USB and Dry contact |
||
Intelligent Slot | Optional SNMP, Modbus and AS-400 cards available | ||||
ENVIRONMENT | |||||
Humidity | 0 ~ 90% RH (Non-Condensing) | ||||
Operating Temperature | 0 to 40°C | -10 to 55°C | |||
Altitude | Max. 2000 m** |
Reviews
There are no reviews yet.